Human CTSV (Cathepsin L2) CLIA Kit

Référence NB-22-40222-1

Conditionnement : 96T

Marque : Neo Biotech

Contactez votre distributeur local :


Téléphone : +1 850 650 7790

  • Human CTSV (Cathepsin L2) CLIA Kit

General Info

Applications: CLIA
Reactivity: Human
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 9.38pg/mL
Detection Limit: 15.63~1000pg/mL
Short Description: This human CTSV kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence

Information

Gene Symbol: CTSV
Gene ID: 1515
Uniprot ID: CATL2_HUMAN
Specificity: This kit recognizes Human CTSV in samples. No significant cross-reactivity or interference between Human CTSV and analogues was observed.
Sample Type: Serum, plasma and other biological fluids

Description

Tissue Specificity Predominantly expressed in the thymus and testis. Also expressed in corneal epithelium, and to a lesser extent in conjunctival epithelium and skin.
Function Cysteine protease. May have an important role in corneal physiology.
Protein Name Cathepsin L2
Cathepsin U
Cathepsin V
Database Links Reactome: R-HSA-1236977
Reactome: R-HSA-1474228
Reactome: R-HSA-1592389
Reactome: R-HSA-1679131
Reactome: R-HSA-2022090
Reactome: R-HSA-2132295
Reactome: R-HSA-8939242
Cellular Localisation Lysosome
Alternative CLIA Names Cathepsin L2 CLIA kit
Cathepsin U CLIA kit
Cathepsin V CLIA kit
CTSV CLIA kit
CATL2 CLIA kit
CTSL2 CLIA kit
CTSU CLIA kit
UNQ268 CLIA kit
PRO305 CLIA kit
Specificity This kit recognizes Human CTSV in samples. No significant cross-reactivity or interference between Human CTSV and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 98-114 105
EDTA plasma(n=8) 96-112 102
Cell culture media(n=8) 97-111 105

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (pg/mL) 50.25 109.20 369.91 46.37 100.73 384.17
Standard deviation 6.16 11.50 29.04 3.83 7.50 27.31
CV (%) 12.26 10.53 7.85 8.26 7.45 7.11
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance