Rat S100A11 (S100 Calcium Binding Protein A11) CLIA Kit

Référence NB-22-42075-1

Conditionnement : 96T

Marque : Neo Biotech

Contactez votre distributeur local :


Téléphone : +1 850 650 7790

  • Rat S100A11 (S100 Calcium Binding Protein A11) CLIA Kit

General Info

Applications: CLIA
Reactivity: Rat
Note: FOR SCIENTIFIC EDUCATIONAL RESEARCH USE ONLY (RUO). MUST NOT BE USED IN DIAGNOSTIC OR OTHER MEDICAL APPLICATIONS.
Sensitivity: 0.19ng/mL
Detection Limit: 0.31~20ng/mL
Short Description: This rat S100A11 kit is a highly sensitive in-vitro chemiluminescent immunoassay for the measurement of trace amounts of analytes.
Storage Instruction: If unopened the kit may be stored at 2-8°C for up to 1 month. If the kit will not be used within 1 month, store the components separately, according to the component table in the manual.
Assay Time: 3.5h
Detection: Chemiluminescence

Information

Gene Symbol: S100a11
Gene ID: 445415
Uniprot ID: S10AB_RAT
Specificity: This kit recognizes Rat S100A11 in samples. No significant cross-reactivity or interference between Rat S100A11 and analogues was observed.
Sample Type: Serum, plasma and other biological fluids

Description

Post Translational Modifications Phosphorylation at Thr-5 significantly suppresses homodimerization and promotes association with NCL/nucleolin which induces nuclear translocation.
Function Facilitates the differentiation and the cornification of keratinocytes.
Protein Name Protein S100-A11
Calgizzarin
S100 Calcium-Binding Protein A11
Database Links Reactome: R-RNO-6798695
Cellular Localisation Cytoplasm
Nucleus
Alternative CLIA Names Protein S100-A11 CLIA kit
Calgizzarin CLIA kit
S100 Calcium-Binding Protein A11 CLIA kit
S100a11 CLIA kit
Specificity This kit recognizes Rat S100A11 in samples. No significant cross-reactivity or interference between Rat S100A11 and analogues was observed.
Reproducibility Both intra-CV and inter-CV are

Information sourced from Uniprot.org


Item Specifications Storage
Micro CLIA Plate (Dismountable) 96T: 8 wells ×12 strips strips -20℃, 6 months
Reference Standard 96T: 2 vials 48T: 1 vial -20℃, 6 months
Concentrated Biotinylated Detection Ab (100×) 96T: 1 vial, 120 μL 60 μL -20℃, 6 months
Concentrated HRP Conjugate (100×) 96T: 1 vial, 120 μL 60 μL -20℃ (Protect from light), 6 months
Reference Standard & Sample Diluent 1 vial, 20 mL 2-8°C, 6 months
Biotinylated Detection Ab Diluent 1 vial, 14 mL 2-8°C, 6 months
HRP Conjugate Diluent 1 vial, 14 mL 2-8°C, 6 months
Concentrated Wash Buffer (25×) 1 vial, 30 mL 2-8°C, 6 months
Substrate Reagent A 1 vial, 5 mL 2-8℃ (Protect from light)
Substrate Reagent B 1 vial, 5 mL 2-8℃ (Protect from light)
Plate Sealer 5 pieces
Manual 1 copy
Certificate of Analysis 1 copy

Sample Type Range (%) Average Recovery (%)
Serum(n=8) 99-114 105
EDTA plasma(n=8) 93-108 100
Cell culture media(n=8) 90-105 96

Intra-assay Precision Intra-assay Precision Intra-assay Precision Inter-assay Precision Inter-assay Precision Inter-assay Precision
Sample 1.00 2.00 3.00 1.00 2.00 3.00
n 20.00 20.00 20.00 20.00 20.00 20.00
Mean (ng/mL) 1.11 2.11 6.84 1.18 1.98 7.41
Standard deviation 0.12 0.22 0.42 0.15 0.20 0.45
CV (%) 10.81 10.43 6.14 12.71 10.10 6.07
12 months for antibodies. 6 months for ELISA Kits. Please see website T&Cs for further guidance